SOP for Multi-Stem Thermometer with external sensing probe

SOP for Multi-Stem Thermometer with external sensing probe

Learn about Standard operating procedures for Multi-Stem thermometers with external sensing probes. Purpose: To lay down procedure for Cleaning & Operating of Multi-Stem Thermometer with external sensing probe. Scope: This procedure is applicable for Multi-Stem Thermometers with external sensing probes used in the company. Responsibility: Accountability: Procedure: Cleaning: Operation of Instrument: Operation: Alarm setting: Precautions: … Read more

SOP for cleaning, operation, and calibration of Muffle Furnace

SOP for cleaning, operation, and calibration of Muffle Furnace

1.0 OBJECTIVE: 1.1 To lay down a procedure for cleaning, operation, and calibration of Muffle Furnace. 2.0 SCOPE: 2.1 This procedure is applicable for Cleaning, Operation, and calibration of Muffle Furnace in Analytical Development in the Pharmaceutical Laboratory. Instrument Id. : XY/XY/001 Location: Fume Hood 3.0 REFERENCE: 3.1 In-House 4.0 RESPONSIBILITY: 4.1 Officer/ Executive-AD shall … Read more

SOP for estimation of Nickel (IS 12122 -1987)

Standard working procedure for estimation of Nickel / Standard Working procedure for Nikel estimation by using AAS Methods. Principle: The Nickel content in the sample is determined by aspirating the sample into the flame of an Atomic Absorption Spectrophotometer after pre-concentration. Measured the Absorbance at 232 nm using a Nickel Hollow Cathode Lamp. Limit of … Read more

SOP for Estimation of Sodium (Part 45)

Standard operating/ Working procedure for Estimation of Sodium, Physical and chemical methods of sampling and test for water and wastewater: Part 45 Sodium Principle: When a sodium-containing solution is put into a flame, the brightness of the light passing through it will decrease depending on how much sodium is in the solution. A special lamp … Read more

SOP for estimation of BORON

Standard Operating procedure for estimation of BORON in Pharmaceutical and scientific labs. Principle: When Azomethine-H, which comes from condensation of H Acid (8-amino-naptha-1-ol-3.6-disulphonic Acid) and Salicyladehyde, reacts with borate in a watery solution with a pH higher than 6, it a yellow complex that we can measure using a spectrophotometer. To understand the yellow complex … Read more

SOP on Reference Standards and impurities

SOP on Reference Standards and impurities

Standard Operating Procedure on Procurement, Storage, Usage, and Destruction of Reference Standards and Impurities. In this SOP you will learn about the following: Related SOP: SOP on Withdrawal, Storage, Observation & Destruction of Control Sample 1.0 Objective: 1.1 To lay down a procedure for the Procurement, Storage, Usage, and Destruction of Reference Standards and impurities.2.0 … Read more

SOP on Working Standards- Preparation, Qualification, Usage, Storage, and Destruction

SOP on Working Standards

Standard operating procedure on Preparation, Qualification, Usage, Storage, and Destruction of Working Standards in Pharmaceutical Labs. Working standard SOP will cover the following points: 1.0 Objective: 1.1 To lay down a procedure for the Preparation, Qualification, Usage, Storage, and Destruction of Working Standards.2.0 Scope: 2.1. This procedure applies to the Preparation, Qualification, Usage, Storage, and … Read more

SOP on Operation of Fume Hood

SOP on Operation of Fume Hood

Standard operating procedure on Operation of Fume Hood and the Precaution to be taken before its operation. 1.0 Purpose: For proper handling of the instrument and to save the environment of the QC laboratory from hazards and corrosive chemicals in the laboratory. 2.0 Scope: This SOP is applicable to all hazards, volatile and corrosive chemicals … Read more

SOP on Procurement, Usage, and Storage of Primary Standards

SOP on Procurement, Usage, and Storage of Primary Standards

Standard Operating procedure on Procurement, Usage, and Storage of Primary Standards in Pharmaceutical Quality control Department. 1.0 Objective: 1.1 To lay down a procedure for Procurement, usage, and storage of primary standards 2.0 Scope: 2.1 This procedure is applicable for the Procurement, usage, and storage of primary standards being used in the Quality Control Department … Read more

SOP for Operation and Calibration of Flame Photometer

SOP for Operation and Calibration of Flame Photometer

Standard operating procedure for Operation and Calibration of Flame Photometer 1.0 Objective: To lay down the procedure for the operation and calibration of the Flame photometer.2.0 Scope: This procedure applies to Flame Photometer instrument installed in the Quality Control Department in Pharmaceutical.3.0 Responsibility: Officer/ Execution responsible for the implementation of this procedure.QC Asst. Manager/ Manager … Read more

SOP for Operation of Digital Griffin Flask Shaker

Digital Griffin Flask Shaker

Standard Operating Procedure for Operation of Digital Griffin Flask Shaker 1.0 Objective: To provide a procedure for operating the digital Griffin flask shaker. 2.0 Scope: The procedure shall be applied when operating the digital Griffin flask shaker in the Q.C Laboratory. 3.0 Responsibility: QC Executive and any personnel using the equipment to follow the outlined … Read more

SOP for Monitoring and Recording Critical Environmental Parameters of Different classes

1.0 Purpose: To describe the procedure for monitoring and recording critical environmental parameters of different classes at the production facility. 2.0 Aim: This Standard Operating Procedure is applicable for monitoring and Recording Critical Environmental Parameters such as temperature, relative humidity, pressure differential, and non-viable particle count of a different class (class A, B, C, and … Read more

SOP for Estimation of Mercury using Atomic Absorption Spectroscopy

SOP for Estimation of Mercury using Atomic Absorption Spectroscopy

Standard Operating Procedure for Estimating Mercury 1.0 Purpose: To lay down the procedure for the Estimation of Mercury using Atomic Absorption Spectroscopy. 2.0 Aim: This Standard Operating procedure is applicable to the Estimation of Mercury using Atomic Absorption Spectroscopy (AAS) in a Pharmaceutical Laboratory. Principle: The method used here, called flameless AAS (Atomic Absorption Spectroscopy), … Read more

SOP on Withdrawal, Storage, Observation & Destruction of Control Sample

SOP on Withdrawal, Storage, Observation & Destruction of Control Sample

Standard Operating Procedure on Withdrawal, Storage, Observation & Destruction of Control/Retention Sample in Pharmaceuticals. 1.0 Objective: This SOP applies to the withdrawal, storage, observation, and destruction of control samples from production (OSD & Injectable) and Quality control (R.M. Retention) in the pharmaceutical formulation plant. 2.0 Scope: This Standard Operating Procedure applies to the withdrawal, storage, … Read more

SOP on Receipt and Handling of Laboratory Samples

SOP on Receipt and Handling of Laboratory Sample

1.0 OBJECTIVE: This procedure outlines the steps for receiving and Handling of Laboratory Samples. 2.0 SCOPE: This standard operating procedure pertains to the receipt and Handling of Laboratory Samples. 3.0 RESPONSIBILITY: The Quality Control Executive/Microbiologist is responsible for the implementation of this SOPThe Assistant Manager QC and/or QA Manager are responsible for Overall compliance with … Read more

SOP on Out of Acceptance Limit in Purified Water System

SOP on Out of Acceptance Limit in Purified Water System

OBJECTIVE: To establish a procedure for action to be taken where critical parameters exceed acceptable limits within the purified water system. SCOPE: This Standard Operating Procedure applies to the generation and distribution of purified water systems. RESPONSIBILITY: Officer, Executive – Engineering Department.Head – Engineering Department for overall compliance to this SOP. ACCOUNTABILITY:Head of Engineering PROCEDURE: … Read more